Sign In | Join Free | My burrillandco.com
Home > Industrial Centrifugal Fans >

Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans

Xinxiang SIMO Blower Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans from wholesalers
     
    Buy cheap Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans from wholesalers
    • Buy cheap Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans from wholesalers
    • Buy cheap Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans from wholesalers
    • Buy cheap Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans from wholesalers
    • Buy cheap Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans from wholesalers

    Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans

    Ask Lasest Price
    Brand Name : SIMO
    Model Number : SIMO Blower 6-06
    Certification : CE, ISO9001:2008,TUV
    Price : Negotiable
    Payment Terms : T/T, L/C, Payment Term Is Negotiable
    Supply Ability : 500 Sets Per Month
    Delivery Time : 15-35 Days
    • Product Details
    • Company Profile

    Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans

    Q345 V-Belt Driving Heat Dissipation Industrial Centrifugal Fans


    Introduction Of Centrifugal Fan


    The 6-06 series boiler fan is mainly used for the fan system of the 2t/h~670t/h steam boiler of the thermal power plant, and also meets the requirements of the performance parameters of the high pressure head of the fluidized bed furnace.

    It’s a widely used medium-pressure heavy-duty centrifugal fan, which is commonly used in industrial systems such as boilers, dust collectors, desulfurization systems, cement, chemicals, metallurgy, electric power, and gas and material transportation. It can also be used for general ventilation.


    Technical data


    seriesmodelRotation Speed
    (r/min)
    Total Pressure
    (Pa)
    Air Capacity
    (m³/h)
    Power
    (kW)
    6-068C145018592745110002640015 ~ 22
    9C145023533474157003750030 ~ 45
    10C145029054289215005150045 ~ 75
    11C960 ~ 145015415190227006850022 ~ 110
    12C960 ~ 145018346176246008900037 ~ 160
    13C960 ~ 1450215272483120011300055 ~ 250
    14C960 ~ 1450249684063900014100075 ~ 400
    15C730 ~ 1450165796503660017200045 ~ 500
    16C730 ~ 14501885109804430021100075 ~ 710
    17C730 ~ 960212854335320016800090 ~ 280
    18C730 ~ 9602386609163100199000110 ~ 355
    19C730 ~ 9602658678774200234000160 ~ 500
    20C730 ~ 9602946752086700273000200 ~ 630
    21C580 ~ 9602050829079500316000200 ~ 800
    22C580 ~ 9602250909992200363000220 ~ 1000
    23.5C580 ~ 960256710380112000443000220 ~ 1400
    25C580 ~ 73067946464134000406000355 ~ 800
    26.5C480 ~ 73022367633132000483000220 ~ 1120
    28C480 ~ 73024968522156000569000315 ~ 1400
    29.5C480 ~ 7302771 ~ 9460183000667000400 ~ 2000

    Application


    1. Install centrifugal fans in mines and tunnels to re-enter fresh air and exhaust dirty air to ensure air circulation in the mines and tunnels.Centrifugal fans can help dust discharge, ensure air transparency in mines and tunnels, and ensure the health of workers in mines and tunnels.

    2. A centrifugal fan is installed in the cooling tower, which not only plays the role of ventilation and ensures the normal operation of the cooling tower, but also plays a positive role in improving the cooling effect of the cooling tower by the large flow wind generated by the centrifugal fan.

    3. Main ventilator in coal mine is an important equipment to ensure normal ventilation in underground mine, which not only affects the production capacity of coal mine, but also is very important to the safety of mining industry.


    Product Advantages


    1.The fan pressure is high, therefore it is especially suitable for 1-20t/h industrial boilers, which equipped with spiral pipes and multi-tube dust collector.

    2.The induced draft fan is made into a single suction, different impeller diameter from 400mm to 3000mm.

    3.The position of the air outlet of the fan is expressed by the angle of the air outlet of the casing."Left" and "Right" can be made into different angles.


    FAQ


    1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

    Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

    If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.


    2. How about your company’s pre-sales service and after-sales service?

    Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

    After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.


    3. Does your company have qualifications?

    Answers: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.

    Quality Q345 V Belt Driving Heat Dissipation Industrial Centrifugal Fans for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xinxiang SIMO Blower Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)