    Brand Name : SIMO
    Model Number : SIMO Blower 6-06
    Certification : CE, ISO9001:2008,TUV
    Price : Negotiable
    Payment Terms : T/T, L/C, Payment Term Is Negotiable
    Supply Ability : 500 Sets Per Month
    Delivery Time : 15-35 Days
    • Product Details
    • Company Profile

    Large Capacity Efficient Energy Saving Backward Induced Draft Fan

    Large Capacity Efficient Energy-Saving Backward Induced Draft Fan


    Introduction Of Centrifugal Fan


    6-06 series centrifugal fan is generally used for gas transportation of granular or powdery materials, and can be widely used to transport air and non-corrosive non-self-igniting, non-viscous substances.

    For the material of impeller and main shaft, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature resistant high-strength alloy steel under different working conditions temperature and working speed, so that the impeller and main shaft still maintains a reliable strength at high temperature.

    Fan systems with impeller diameters less than 1400 mm at normal temperature do not require additional bearing cooling devices, reducing users’ investment and maintenance.


    Technical data


    seriesmodelRotation Speed
    (r/min)
    Total Pressure
    (Pa)
    Air Capacity
    (m³/h)
    Power
    (kW)
    6-068D145018592745110002640015 ~ 22
    9D145023533474157003750030 ~ 45
    10D145029054289215005150045 ~ 75
    11D960 ~ 145015415190227006850022 ~ 110
    12D960 ~ 145018346176246008900037 ~ 160
    13D960 ~ 1450215272483120011300055 ~ 250
    14D960 ~ 1450249684063900014100075 ~ 400
    15D730 ~ 1450165796503660017200045 ~ 500
    16D730 ~ 14501885109804430021100075 ~ 710
    17D730 ~ 960212854335320016800090 ~ 280
    18D730 ~ 9602386609163100199000110 ~ 355
    19D730 ~ 9602658678774200234000160 ~ 500
    20D730 ~ 9602946752086700273000200 ~ 630
    21D580 ~ 9602050829079500316000200 ~ 800
    22D580 ~ 9602250909992200363000220 ~ 1000
    23.5D580 ~ 960256710380112000443000220 ~ 1400
    25D580 ~ 73067946464134000406000355 ~ 800
    26.5D480 ~ 73022367633132000483000220 ~ 1120
    28D480 ~ 73024968522156000569000315 ~ 1400
    29.5D480 ~ 7302771 ~ 9460183000667000400 ~ 2000

    Product Advantages


    1.It can output higher outlet pressure and provide more gas flow at the same time, low noise.

    2. The fan speed can be flexibly set by matching different belt pulley diameters to make the fan run at the highest efficiency point and reduce energy waste.

    3. Motor slide guide can be provided for convenient belt tensioning to reduce energy loss caused by belt slack.

    4. The bearing housing is reserved for the installation position of temperature and vibration sensors, which can facilitate the installation of fan operation monitoring device.

    5. Use liquid lubricating oil. It is not necessary to open the bearing housing to replace and fill the lubricating oil. The bearing housing is provided with an observation window for easy observation of the quality and stock of the lubricating oil.

    6. The bearing housing uses labyrinth mechanical seal, unique anti-leakage design inside, vent hole at the top, and sealing grease at the joint, completely eliminating the possibility of oil leakage in the bearing hosing.


    FAQ


    1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

    Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

    If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.


    2. How about your company’s pre-sales service and after-sales service?

    Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

    After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.


    3. Does your company have qualifications?

    Answers: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.